sanic/tests/worker/test_manager.py

306 lines
8.2 KiB
Python
Raw Normal View History

2022-12-13 07:28:23 +00:00
from logging import ERROR, INFO
2022-12-15 09:49:26 +00:00
from signal import SIGINT
from unittest.mock import Mock, call, patch
import pytest
2022-12-15 09:49:26 +00:00
from sanic.compat import OS_IS_WINDOWS
from sanic.exceptions import ServerKilled
2022-12-18 12:09:17 +00:00
from sanic.worker.constants import RestartOrder
from sanic.worker.manager import WorkerManager
2022-12-15 09:49:26 +00:00
if not OS_IS_WINDOWS:
from signal import SIGKILL
else:
SIGKILL = SIGINT
def fake_serve():
...
def test_manager_no_workers():
message = "Cannot serve with no workers"
with pytest.raises(RuntimeError, match=message):
2022-12-13 07:28:23 +00:00
WorkerManager(0, fake_serve, {}, Mock(), (Mock(), Mock()), {})
@patch("sanic.worker.process.os")
def test_terminate(os_mock: Mock):
process = Mock()
process.pid = 1234
context = Mock()
context.Process.return_value = process
2022-12-13 07:28:23 +00:00
manager = WorkerManager(1, fake_serve, {}, context, (Mock(), Mock()), {})
manager.terminate()
os_mock.kill.assert_called_once_with(1234, SIGINT)
@patch("sanic.worker.process.os")
def test_shutown(os_mock: Mock):
process = Mock()
process.pid = 1234
process.is_alive.return_value = True
context = Mock()
context.Process.return_value = process
2022-12-13 07:28:23 +00:00
manager = WorkerManager(1, fake_serve, {}, context, (Mock(), Mock()), {})
manager.shutdown()
os_mock.kill.assert_called_once_with(1234, SIGINT)
@patch("sanic.worker.manager.os")
def test_kill(os_mock: Mock):
process = Mock()
process.pid = 1234
context = Mock()
context.Process.return_value = process
2022-12-13 07:28:23 +00:00
manager = WorkerManager(1, fake_serve, {}, context, (Mock(), Mock()), {})
with pytest.raises(ServerKilled):
manager.kill()
os_mock.kill.assert_called_once_with(1234, SIGKILL)
2022-12-18 12:40:38 +00:00
@patch("sanic.worker.process.os")
@patch("sanic.worker.manager.os")
def test_shutdown_signal_send_kill(
manager_os_mock: Mock, process_os_mock: Mock
):
process = Mock()
process.pid = 1234
context = Mock()
context.Process.return_value = process
manager = WorkerManager(1, fake_serve, {}, context, (Mock(), Mock()), {})
assert manager._shutting_down is False
manager.shutdown_signal(SIGINT, None)
assert manager._shutting_down is True
process_os_mock.kill.assert_called_once_with(1234, SIGINT)
manager.shutdown_signal(SIGINT, None)
manager_os_mock.kill.assert_called_once_with(1234, SIGKILL)
def test_restart_all():
p1 = Mock()
p2 = Mock()
context = Mock()
context.Process.side_effect = [p1, p2, p1, p2]
2022-12-13 07:28:23 +00:00
manager = WorkerManager(2, fake_serve, {}, context, (Mock(), Mock()), {})
assert len(list(manager.transient_processes))
manager.restart()
p1.terminate.assert_called_once()
p2.terminate.assert_called_once()
context.Process.assert_has_calls(
[
call(
name="Sanic-Server-0-0",
target=fake_serve,
kwargs={"config": {}},
daemon=True,
),
call(
name="Sanic-Server-1-0",
target=fake_serve,
kwargs={"config": {}},
daemon=True,
),
call(
name="Sanic-Server-0-0",
target=fake_serve,
kwargs={"config": {}},
daemon=True,
),
call(
name="Sanic-Server-1-0",
target=fake_serve,
kwargs={"config": {}},
daemon=True,
),
]
)
2022-12-18 12:09:17 +00:00
@pytest.mark.parametrize("zero_downtime", (False, True))
def test_monitor_all(zero_downtime):
p1 = Mock()
p2 = Mock()
sub = Mock()
2022-12-18 12:09:17 +00:00
incoming = (
"__ALL_PROCESSES__::STARTUP_FIRST"
if zero_downtime
else "__ALL_PROCESSES__:"
)
sub.recv.side_effect = [incoming, ""]
context = Mock()
context.Process.side_effect = [p1, p2]
2022-12-13 07:28:23 +00:00
manager = WorkerManager(2, fake_serve, {}, context, (Mock(), sub), {})
manager.restart = Mock() # type: ignore
manager.wait_for_ack = Mock() # type: ignore
manager.monitor()
2022-12-18 12:09:17 +00:00
restart_order = (
RestartOrder.STARTUP_FIRST
if zero_downtime
else RestartOrder.SHUTDOWN_FIRST
)
manager.restart.assert_called_once_with(
2022-12-18 12:09:17 +00:00
process_names=None,
reloaded_files="",
restart_order=restart_order,
)
2022-12-18 12:09:17 +00:00
@pytest.mark.parametrize("zero_downtime", (False, True))
def test_monitor_all_with_files(zero_downtime):
p1 = Mock()
p2 = Mock()
sub = Mock()
2022-12-18 12:09:17 +00:00
incoming = (
"__ALL_PROCESSES__:foo,bar:STARTUP_FIRST"
if zero_downtime
else "__ALL_PROCESSES__:foo,bar"
)
sub.recv.side_effect = [incoming, ""]
context = Mock()
context.Process.side_effect = [p1, p2]
2022-12-13 07:28:23 +00:00
manager = WorkerManager(2, fake_serve, {}, context, (Mock(), sub), {})
manager.restart = Mock() # type: ignore
manager.wait_for_ack = Mock() # type: ignore
manager.monitor()
2022-12-18 12:09:17 +00:00
restart_order = (
RestartOrder.STARTUP_FIRST
if zero_downtime
else RestartOrder.SHUTDOWN_FIRST
)
manager.restart.assert_called_once_with(
2022-12-18 12:09:17 +00:00
process_names=None,
reloaded_files="foo,bar",
restart_order=restart_order,
)
2022-12-18 12:09:17 +00:00
@pytest.mark.parametrize("zero_downtime", (False, True))
def test_monitor_one_process(zero_downtime):
p1 = Mock()
p1.name = "Testing"
p2 = Mock()
sub = Mock()
2022-12-18 12:09:17 +00:00
incoming = (
f"{p1.name}:foo,bar:STARTUP_FIRST"
if zero_downtime
else f"{p1.name}:foo,bar"
)
sub.recv.side_effect = [incoming, ""]
context = Mock()
context.Process.side_effect = [p1, p2]
2022-12-13 07:28:23 +00:00
manager = WorkerManager(2, fake_serve, {}, context, (Mock(), sub), {})
manager.restart = Mock() # type: ignore
manager.wait_for_ack = Mock() # type: ignore
manager.monitor()
2022-12-18 12:09:17 +00:00
restart_order = (
RestartOrder.STARTUP_FIRST
if zero_downtime
else RestartOrder.SHUTDOWN_FIRST
)
manager.restart.assert_called_once_with(
2022-12-18 12:09:17 +00:00
process_names=[p1.name],
reloaded_files="foo,bar",
restart_order=restart_order,
)
def test_shutdown_signal():
pub = Mock()
2022-12-13 07:28:23 +00:00
manager = WorkerManager(1, fake_serve, {}, Mock(), (pub, Mock()), {})
manager.shutdown = Mock() # type: ignore
manager.shutdown_signal(SIGINT, None)
pub.send.assert_called_with(None)
manager.shutdown.assert_called_once_with()
2022-12-13 07:28:23 +00:00
def test_shutdown_servers(caplog):
p1 = Mock()
p1.pid = 1234
context = Mock()
context.Process.side_effect = [p1]
pub = Mock()
manager = WorkerManager(1, fake_serve, {}, context, (pub, Mock()), {})
with patch("os.kill") as kill:
with caplog.at_level(ERROR):
manager.shutdown_server()
kill.assert_called_once_with(1234, SIGINT)
kill.reset_mock()
assert not caplog.record_tuples
manager.shutdown_server()
kill.assert_not_called()
assert (
"sanic.error",
ERROR,
"Server shutdown failed because a server was not found.",
) in caplog.record_tuples
def test_shutdown_servers_named():
p1 = Mock()
p1.pid = 1234
p2 = Mock()
p2.pid = 6543
context = Mock()
context.Process.side_effect = [p1, p2]
pub = Mock()
manager = WorkerManager(2, fake_serve, {}, context, (pub, Mock()), {})
with patch("os.kill") as kill:
with pytest.raises(KeyError):
manager.shutdown_server("foo")
manager.shutdown_server("Server-1")
kill.assert_called_once_with(6543, SIGINT)
def test_scale(caplog):
p1 = Mock()
p1.pid = 1234
p2 = Mock()
p2.pid = 3456
p3 = Mock()
p3.pid = 5678
context = Mock()
context.Process.side_effect = [p1, p2, p3]
pub = Mock()
manager = WorkerManager(1, fake_serve, {}, context, (pub, Mock()), {})
assert len(manager.transient) == 1
manager.scale(3)
assert len(manager.transient) == 3
with patch("os.kill") as kill:
manager.scale(2)
assert len(manager.transient) == 2
manager.scale(1)
assert len(manager.transient) == 1
kill.call_count == 2
with caplog.at_level(INFO):
manager.scale(1)
assert (
"sanic.root",
INFO,
"No change needed. There are already 1 workers.",
) in caplog.record_tuples
with pytest.raises(ValueError, match=r"Cannot scale to 0 workers\."):
manager.scale(0)